Single Phase House Wiring Diagram / Energy Meter / Single Phase DB Wiring
HTML-код
- Опубликовано: 29 мар 2025
- In this video, I try to explain the concept of single phase house wiring system with intituled electrical components. And also this video describes how electricity reaches our homes from the electric pole, single phase energy meter, main isolation switch (DP MCB), RCCB and SP MCB, switches, lights, socket outlets and how electricity works in the house.
220 to 240 volts are used in our single phase house wiring. SP MCB automatically switches off during an abnormal condition of the house electrical network means in overload condition as well as faulty condition.
DP MCB - Double Pole Miniature Circuit Breaker
RCCB - Residual Current Circuit Breaker
SP MCB - Single Pole Miniature Circuit Breaker
DB - Distribution Board
If you have any questions about single phase house wiring please comment below the video. I will answer your questions.
Thanks for watching this video.
PLEASE LIKE, SHARE AND SUBSCRIBE THIS CHANNEL.
/ @slengineeringacademy2234
💻Connect with SL Engineering Academy
🌐Facebook 📲 m.facebook.com...
More video
Complete Electrical House Wiring / Single Phase Full House Wiring Diagram
• Complete Electrical Ho...
Two Way Switch Connection / How to Wire 2 Way Light Switch / Starecase Wiring with 2 Way Switch
• Two Way Switch Connect...
Automatic Changeover Switch for Generator / Automatic Transfer Switch / ATS (With Circuit Diagram)
• Automatic Changeover S...
DOL Starter Connection with Indicator | 3 Phase Direct On Line Starter/ Explain with Circuit Diagram
• DOL Starter Connection...
Star Delta Starter for 3 Phase Induction Motor / Star Delta Connection
• Star Delta Starter for...
Float Switch Wiring Diagram for Water Pump/ How to Make Automatic On-Off Switch for Water Pump
• Float Switch Wiring Di...
Float Switch Connection with Auto & Manual Selector Switch for Single Phase Water Pump
• Float Switch Connectio...
How to Wire Ceiling Fan and Fan Regulator / Ceiling Fan Connection / Fan Regulator Connection
• How to Wire Ceiling Fa...
3 Phase Distribution Board Layout and Wiring Diagram
• 3 Phase Distribution B...
Earth Leakage Relay - ELR / How to Wire ELR & CBCT with MCCB / Working Principle of ELR
• Earth Leakage Relay - ...
Single Phase Split Type Air Conditioner(AC) Indoor & Outdoor Wiring Diagram/ How to Wire Split AC
• Single Phase Split Typ...
Thanks for Watching.❤👍
Please Subscribe the Channel.
This is the best graphic explanation on how single phase power work and how is distributed from the mains power post to the house power board thank you .
অনেক ভালো লাগলো এরকম আরো ভিডিও চাই কিছু শিখতে পারলাম
Very simple and clear explanation . Really helpful Video . Thank you ❤
Excelent sir very clear explation 🥰❤️all world people must and should watch this video.... Mind blowing teaching sir❤️❤️❤️❤️❤️god bless you sir💞💞💞💞leave live Long Long day's sir🧡🧡🧡🧡🧡
Thank you♥️
Very clear and straight forward
Wah Bhai jaan must video Aapka btane k trika bahut must h 👍
very nice👍👍👍👍👍 need more please about wiring
Thanks for watching..❤👍👍
Not quite sure where you are located, but in most countries lighting circuits also require the earth wire, even though incandescent globes do not have an earth terminal. Other lighting devices will require it, as will fittings that are not double insulated. The basics of this diagram though are absolutely how you'd do it and are a really good guide. With this said, if a person needed a guide like this they should not really be touching a switchboard / distriibution board / consumer unit and should be referring to someone qualified. A warning on this video about the dangers etc etc etc would be nice.
Note on the fan circuit. If the fan is on the lighting circuit as depicted, you would not run a separate neutral back to the neutral bar. You'd just have it on the same neutral as the lighting circuit. If you are running twin and earth back to the board for the fan, you might as well just have the fan on it's own circuit.
ખૂબ ઉપયોગી માહિતી આપો સો ભાઈ
ખૂબ ખૂબ આભાર 🙏🙏🙏
This is so helpfull to me ,Thank you sir'
Most perfect guide for single phase.
Thanks, for the demonstration, please if you can , prepare for us also 3 phase wiring for 3 strorey hotel, thanks
Very nice Explanation thanks.keep it up 🙏🙏
👍❤👍
Our miss recommend this must watch🎉🎉🎉🎉🎉🎉
Very clear lesson. Very useful. Thank you so much.
Thanks for watching❤👍
V 😂😂 Ff ff zfzfzzzzzxq Ff z fZzf f. Fit asex CD d
thank you very much ;bien expliqué;merci......./
Very easy to understand. Thanks
👍❤👍
Very nice .
Thank you Sir
very easy and best method
Q : Why dont connect between neutral busbar and ground busbar ? Thank you
i think it's different things between neutral busbar and ground busbar, neutral busbar is a condition when we want to install the electrical component, while the ground busbar for carry leakage current to the earth/ground.
Definitely requires an MEN link between neutral and earth busbars.
هناك طريقتين للتاريض
هو استعمل الاسلوب الذي الارضي غير متصل مع المحايد وهذا صحيح
وحتى لو كانا متصلان يكون ذلك خارج البيت
@@Yazmanyazmanyazman
not understand😅
Nice information
I truly love this video❤❤❤
❤👍❤
Thanks for sharing
👌👌♥️ supered brother💪
Thanks brother❤❤👍👍
This is genius
So great idea
Super bro loved it
Thanks bro
WOW SO CLEAR THANK YOU SO MUCH
Some videos show how to connect the main wire at the top. But here you show how to connect the bottom. Is there a difference? Explain a little
what application can draw like that??? thank you SL Engineering Academy for sharing idea.
Very nice thanks for teaching
❤👍
Good understanding
Supiri mybro
Thanks bro❤
Show de bola 👏👏👏👍👍👍👍
Why is the ceiling fan the one connected to the ground? Or all of the other appliances connected to the same SP MCB are already connected to the ground since the ceiling fan is? If so, are the only ones connected to the ground are the appliances connected to that particular SP MCB? Or the other SP MCBs are also connected as well as all the other appliances with it?
In the mountine like that line 1hot line2 ground
Good joob👍🏻
Please can you explain why both the two supply cables from the pole have the same direction for power supply. I thought the direction of the return cable would be backwards
Quick question, If i have
1 × 30A stove circuit breaker
1 × 40A circuit breaker for the inverter inlet
2 × 15A circuit breakers foe the plugs
2 × 5A circuit breaker for the lights, what should be the current rating for my Main circuit Breaker, will i be fine with a double pole 63A MCB?
63A is quite anough
NICE 1
Nice bro !
Thanks bro.❤
great
Akash babu is the best💯
👌
Superb
Thank you.👍
Ayyoo macam ni😂
May l ask someting
When you set up newtonlight
You don t take newtonlight
Come to batbar grow befor
and then can you take
onemore newtonlightlight
from batbargrow
come to (n) newtonlight under
brecker main
Thank you so much 🤟
Super ❤ 2024
The MEN rule says that at the main switchboard the earth shall be connected to neutral
Sir Where did the green wire connected is it connected to grounding Rod? And where is Neutral connected too?
Yes. Green wire should be connected to grounding rod. Neutral connection also come from electric pole as well as live connection.
❤where's your earth goes?😊
To ground through the earth electrode.
Thanks for watching ❤👍
Please what's the difference between MCB and RCCB.
Thanks
MCBs are effectively used to prevent any damage to the circuit or the electrical appliance during a sudden electrical surge. An RCCB circuit breaker, on the other hand, is meant primarily for the safety of human beings.
MCB allows only certain level of current to flow and it breaks the circuit when current more than limiting current flows at the time of shortcircuit Or overload. RCCB is also for safety but it works in completely different principle. It always compare the current in live wire and neutral wire and breaks the circuit when they are not same(for normal condition, currents in both wire should be same). Eg. U get electric shocked when current frm live wire flows through u to the ground (earth) without flowing back to neutral wire. Here, RCCB detects unequal current and gets itself into action.
PS: answering for other viewers too in case they get same question.
@@rewardk me cleared about Rccb mcb. But electrical shop man told if there is no good earthing it will be difficult getting line power because rccb shutoff.
Even a small leakage it will detect.
Nice viveo
Please tell me which software you used to do this ?
Kinemaster
Good
great illustrations
❤👍❤
Please tell how you make this type video
❤❤❤
Good thx
same for stove? Just thicker wires?
Shouldn't the ground and neutral bars be bonded together?
state of art
Which software did you use tp draw this???
Sa diagram, ang neutral at earth, dapat hindi connected,, kung pwede bat ka pa nag hiwalay ng connection, e pwede naman pala ipag sama!
Supper
Nice
🤝🤝🤝👏👏👏👏👏👏👏
Grate
Thanks you
If you can, please send/post/ ppt notes.since it helps to read as a manual
Kitna kitna apere ka mcb use kiya batao bhai
in which software u make this
very depressing music but great video.
Please, software you used to create this ?
ভাই আমি ঘরের মেইন লাইন থেকে ১৮৫০-২২০০ ওয়াটের ইলেক্ট্রিক কেটলি চালাইবো।এখানে কতো RM কেবল দিবো???
1 sp mcb support how many socket/lamp??
1 each if possible
Greta simulation
Thank you..❤👍
where is the ground for light? in Romania the standard is al consumtion must have ground . exxept switch
උඩ පැත්තෙන් නෙවෙයිද supply in කරන්නෙ?
جيد شكرا
We need reasons why bulb is connected in parallel
de ce nu pui sigurante intre retea si contor???
Bro turned off the light at the end of the video 👌😃
Bagus
No no why is yr connection starting from the bottom and not from the top with bussbar . 2nd comment is real very misleading very very dangerous.
Exactly what I was thinking, scared zero knowledge people will refer this 100% without knowing function of busbar
How to making this video please tell me??
Im looking for advice. If someone can please help me. Im renting a unit in a complex. The landlord gives me utility bills that have ridiculous amounts. And it jus goes up. In 3 months the consumption went from 584 to 1047. I asked for him to send me photos of the readings. I dont even know what im paying for.
I hardly used electricity as im not at home 80% of the time.
Hes taking chances because im a woman and know i dont know.
Pls can someone explain. Its a whatt hour meter its says on bottom single phase 2 wire . It has 5 digits and a red counter just next to it.
The meter boxes of all the units are installed further down the complex.
Pls can someone tell me how would i make sure that im not being taken advantage of. And what should i look out for. This stuff is greek for me
c'est bien
It remain how to connect it to the distribution board
In what software can I draw a colored electrical diagram with components that I can add to the diagram
Have you get the software brother
@@sahalshire9307 לא הבנתי. מה השם של התוכנה?
This is misleading and downright WRONG standards enter a MCB at the top and exit at the bottom
Can you please elaborate?
Nothing wrong. I did usually
Anything is possible as long as there is no earth wire and no electrical voltage 😢
This doesn't matter whether up or down what matters is you get the right connections according to the instructions given as per MCB
What safety fuse they used?
how to adjust the speed variator brand vieche 2.2kw
MCB rating used?
what is the software ur using to do this video?
Have you get the software name
Je suis intéressée par ça
Name of the simulator
In all videos I could see amps are not clear than how to select MCB and do wiring .
Right question
mcb rcbc can you show us.
Why fan needs earth wire?